Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-51
(6) Adjustment of the Multi Bypass Table Reference Position
z Requirement
<OPTION>
1151D024AA
D Ready a test chart (A3 or 11 17) as shown on the left.
Draw a line on the chart at a point 20 mm from the right
edge as shown.
D Dimension A on the copy should measure
20 ± 2.0 mm.
1. Place the test chart face down on the Original Glass and
align its rear left corner with the marker on the Original
Width Scale on the left side of the platen.
Then, lower the Original Cover.
2. Using the Multi Bypass Table, make two full size copies.
3. Using the second copy, compare the position of the refer-
ence line on the copy with that on the test chart.
4. If the line does not meet the requirement, loosen the two
screws (OPTION : three screws) that secure the Multi By-
pass Table and move the Table as necessary in the direc-
tion of the arrows.
NOTE
If dimension A on the copy is smaller than 18 mm, move
the Table to the front. If it is more than 22 mm, move the
Table to the rear.
When an Automatic or Duplexing Document Feeder is
mounted, it involves changing the Original Glass. This in
turn results in the position of the Original Length Scale be-
ing slightly shifted toward the rear. This is corrected by
installing the Original Positioning Plate.