When a Message Appears Chapter 6
5. When the Message “The Fuser Oil has run out.” Appears
The message shown on the left appears when the
Fuser Oil is running out. You can still make copies,
but it is recommended that you replenish the Fuser Oil
as soon as possible.
When Fuser Oil has run out, the message shown on
the left appears and you can no longer start a new
copy cycle. Replenish the Fuser Oil by following the
procedure given below.
Usually, the Fuser Oil replenishment should be performed by a qualified service representative.
However, on an as need basis, the Copier can be set so that a trained operator can replenish the
Fuser Oil. In this case, we recommend that only a trained key operator replenish the Fuser Oil
according to the following procedure.
Replenishing the Fuser Oil
Open the Front Door.
Turn the Lever to the left. Grasp the
Lever and slide out the Transfer/
Fusing Unit.
1179P427CA
1179P426CA
1
1179O025AA
2
M4